THHW-500MCM
Polar Wire
WARNING: Cancer and Reproductive Harm - www.p65warnings.ca.gov
THHW/TEW/MTW/AWM/CT
Multi Listed Flexible Wire
500 MCM
Legend: 500 MCM (253mm2) E321440K (UL) MTW OR THHW FOR CT USE OR AWM 1339 600V OR 10269 1000V VW-1 --- 500 MCM LL604009 AWM I A/B 600V 105°C FT1 FT2
Polar Wire combines finely stranded annealed copper conductors with an extra-flexible, fire retardant PVC jacket for a multipurpose flexible wire that handles better, reduces installation effort, and performs to the highest standards
Single Conductor Multi Listed Flexible Wire is a Class K flexing service wire made with 30 AWG fine conductor stranding for superior flexibility. Constructed of soft annealed bare copper (NO ALUMINUM!) to ASTM Specification B172. Insulated with an extra-flexible extruded, high dielectric PVC jacket that resists abrasion, oils, acids, heat, flame, and moisture, and performs reliably in severe cold temperatures and high heat conditions.
THHW/TEW/MTW/AWM//CT Multi Listed Flexible Wire holds multiple ratings and certifications:
![]()
Multi Listed Flexible Wire (THHW)
Features:
Applications:
Industry Approvals:
![]()
-40°C to 105°C
Construction Specifications:
Class K Finely Stranded Multi Listed Flexible Wire
*Available by special order, minimums may apply
**The ampacities provided are for informational purposes only. Acceptance of these values by any governing body is the responsibility of the end user. Ampacities are based on a single conductor, in free air, at 30°C ambient air temperature. 105°C ampacities adapted from ICEA P-54-440/NEMA WC51-1986 R1991)


THHW-500MCM
Bare Copper
Class K (5054/30)
.095"
1.160"
500 MCM
1
1.93 lb
700*
620*
-40°F to 221°F (-40°C to 105°C)
600V
*Ampacities of 600V and 1000V 105°C AWM wires in air. Ampacities based on single conductor in free air, 30°C or 40°C ambient temperature as specified, 105°C conductor temperature, per NEC table 310-17 (adjusted for 105°C). Free air ratings assume a one-cable-diameter space between adjacent conductors.
Item Number: THHW-500MCMBLK
Wed, Oct 7 - Thu, Oct 8
Order within 7h 17m
Polar Wire
Item Number: THHW-500MCMBLK
WARNING: Cancer and Reproductive Harm - www.p65warnings.ca.gov

Wed, Oct 7 - Thu, Oct 8
Order within 7h 17m
THHW-500MCM
Bare Copper
Class K (5054/30)
.095"
1.160"
500 MCM
1
1.93 lb
700*
620*
-40°F to 221°F (-40°C to 105°C)
600V
*Ampacities of 600V and 1000V 105°C AWM wires in air. Ampacities based on single conductor in free air, 30°C or 40°C ambient temperature as specified, 105°C conductor temperature, per NEC table 310-17 (adjusted for 105°C). Free air ratings assume a one-cable-diameter space between adjacent conductors.
THHW/TEW/MTW/AWM/CT
Multi Listed Flexible Wire
500 MCM
Legend: 500 MCM (253mm2) E321440K (UL) MTW OR THHW FOR CT USE OR AWM 1339 600V OR 10269 1000V VW-1 --- 500 MCM LL604009 AWM I A/B 600V 105°C FT1 FT2
Polar Wire combines finely stranded annealed copper conductors with an extra-flexible, fire retardant PVC jacket for a multipurpose flexible wire that handles better, reduces installation effort, and performs to the highest standards
Single Conductor Multi Listed Flexible Wire is a Class K flexing service wire made with 30 AWG fine conductor stranding for superior flexibility. Constructed of soft annealed bare copper (NO ALUMINUM!) to ASTM Specification B172. Insulated with an extra-flexible extruded, high dielectric PVC jacket that resists abrasion, oils, acids, heat, flame, and moisture, and performs reliably in severe cold temperatures and high heat conditions.
THHW/TEW/MTW/AWM//CT Multi Listed Flexible Wire holds multiple ratings and certifications:
![]()
Multi Listed Flexible Wire (THHW)
Features:
Applications:
Industry Approvals:
![]()
-40°C to 105°C
Construction Specifications:
Class K Finely Stranded Multi Listed Flexible Wire
*Available by special order, minimums may apply
**The ampacities provided are for informational purposes only. Acceptance of these values by any governing body is the responsibility of the end user. Ampacities are based on a single conductor, in free air, at 30°C ambient air temperature. 105°C ampacities adapted from ICEA P-54-440/NEMA WC51-1986 R1991)

ArrivesWed, Oct 7 - Thu, Oct 8

ArrivesWed, Oct 7 - Thu, Oct 8

ArrivesWed, Oct 7 - Thu, Oct 8

ArrivesWed, Oct 7 - Thu, Oct 8

ArrivesWed, Oct 7 - Thu, Oct 8